Maintenance of common sense filling machineThis article is collected and posted by Filling Machine-Water Filling Machine-Juice Filling Machine-Water Filling-Juice Filling-Water Treatment-Reverse Osmosis-Mineral Water Plant-Bottle Filling Machine-5 Gallon Filling Machine-Beverage Machine Manufacturer-Automatic Filling Machine-Suzhou King Best Machinery Co.,Ltd. It is not allowed to re-post without our permission. Maintenance of common sense filling machine A filling machine does not start: 1 power on, turn on the power switch, check the fuse. 2 release emergency stop button. 3 is turned on the pressure, maintained at about 6 kg. 4 Check whether there DC24V switching power supply output. 5 Check the touch screen and PLC communication cable is loose. Two: filling machine less than expected: 1 Check the air pressure, check the touch screen repair screen under way. 2 feed mouth is closed, check the circuit. 3 feeding. 4 Check the air pressure, check whether the injection cylinder and the cylinder and die, touch screen repair under way to check the screen material mouth is closed, check the circuit. Three: Filling dose allowed: 1 Check the feed system. 2 pairs of filter material, cleaning pipes. 3 Replace the pneumatic valve seals, pipe leaks, replace the pneumatic valve. 4 cleaning solenoid valve, replace the solenoid valve. 5 clean air silencer, replacement muffler gas. 6 Ball reduce the impact of adjustments to increase dive depth. 7 Replace the O-ring. 8 adjust injection cylinder magnetic switch. Four: Filling Machine leakage: 1 Tighten the cutting nozzle, cutting nozzle gasket replacement. 2 Replace the cutting tube. 3 cleaning pneumatic valve, pneumatic valve replacement gasket. 4 Replace the injection cylinder seals. |